Hydraulic model studies - Aeration of the submerged jet - Flow gates at seminoe dam / Frizell, K. W.
Titre : Hydraulic model studies - Aeration of the submerged jet - Flow gates at seminoe dam Type de document : texte imprimé Auteurs : Frizell, K. W. Mention d'édition : U.S. Departement of the interior Editeur : U.S. Departement of the Interior Année de publication : 1990 ISBN/ISSN/EAN : CI-06871 Note générale : A study was performed to evaluate placement of an aeration vent on a submerged jet. Flow gate at seminoe dam. Size restrictions on the discharge tube downs tream from the gate suggested aeration as a means to project the downstream areas from cavitation damage. Four air vent location were tested. The vent on the top centerline of the discharge tube just downstream of the gate frame performed the best. Ratios of Qo/Qw greater than 10 percent were measured throught the entire range of gate openings. A minimum vent size of 16 inches in diameter is needed to keep air velocities through the vent below 200 p+/S. Langues : Anglais (eng) Mots-clés : Hydraulique Equipement Aeration Modèle hydraulique Submergence Cavitation Index. décimale : 621.2 Hydraulique : turbines, pompes, accumulateurs, transmission hydraulique Résumé : A study was performed to evaluate placement of an aeration vent on a submerged jet. Flow gate at seminoe dam. Size restrictions on the discharge tube downs tream from the gate suggested aeration as a means to project the downstream areas from cavitation damage. Four air vent location were tested. The vent on the top centerline of the discharge tube just downstream of the gate frame performed the best. Ratios of Qo/Qw greater than 10 percent were measured throught the entire range of gate openings. A minimum vent size of 16 inches in diameter is needed to keep air velocities through the vent below 200 p+/S. Note de contenu : A study was performed to evaluate placement of an aeration vent on a submerged jet. Flow gate at seminoe dam. Size restrictions on the discharge tube downs tream from the gate suggested aeration as a means to project the downstream areas from cavitation damage. Four air vent location were tested. The vent on the top centerline of the discharge tube just downstream of the gate frame performed the best. Ratios of Qo/Qw greater than 10 percent were measured throught the entire range of gate openings. A minimum vent size of 16 inches in diameter is needed to keep air velocities through the vent below 200 p+/S. Hydraulic model studies - Aeration of the submerged jet - Flow gates at seminoe dam [texte imprimé] / Frizell, K. W. . - U.S. Departement of the interior . - U.S. Departement of the Interior, 1990.
ISSN : CI-06871
A study was performed to evaluate placement of an aeration vent on a submerged jet. Flow gate at seminoe dam. Size restrictions on the discharge tube downs tream from the gate suggested aeration as a means to project the downstream areas from cavitation damage. Four air vent location were tested. The vent on the top centerline of the discharge tube just downstream of the gate frame performed the best. Ratios of Qo/Qw greater than 10 percent were measured throught the entire range of gate openings. A minimum vent size of 16 inches in diameter is needed to keep air velocities through the vent below 200 p+/S.
Langues : Anglais (eng)
Mots-clés : Hydraulique Equipement Aeration Modèle hydraulique Submergence Cavitation Index. décimale : 621.2 Hydraulique : turbines, pompes, accumulateurs, transmission hydraulique Résumé : A study was performed to evaluate placement of an aeration vent on a submerged jet. Flow gate at seminoe dam. Size restrictions on the discharge tube downs tream from the gate suggested aeration as a means to project the downstream areas from cavitation damage. Four air vent location were tested. The vent on the top centerline of the discharge tube just downstream of the gate frame performed the best. Ratios of Qo/Qw greater than 10 percent were measured throught the entire range of gate openings. A minimum vent size of 16 inches in diameter is needed to keep air velocities through the vent below 200 p+/S. Note de contenu : A study was performed to evaluate placement of an aeration vent on a submerged jet. Flow gate at seminoe dam. Size restrictions on the discharge tube downs tream from the gate suggested aeration as a means to project the downstream areas from cavitation damage. Four air vent location were tested. The vent on the top centerline of the discharge tube just downstream of the gate frame performed the best. Ratios of Qo/Qw greater than 10 percent were measured throught the entire range of gate openings. A minimum vent size of 16 inches in diameter is needed to keep air velocities through the vent below 200 p+/S. Réservation
Réserver ce document
Exemplaires(8)
Code-barres Cote Support Localisation Section Disponibilité CI03B871.49040 CI-06871 Monographie Bibliothèque CDI-Ouaga Fond documentaire Disponible CI03B871.49039 CI-06871 Monographie Bibliothèque CDI-Ouaga Fond documentaire Disponible CI03B871.49038 CI-06871 Monographie Bibliothèque CDI-Ouaga Fond documentaire Disponible CI03B871.49037 CI-06871 Monographie Bibliothèque CDI-Ouaga Fond documentaire Disponible CI03B871.49036 CI-06871 Monographie Bibliothèque CDI-Ouaga Fond documentaire Disponible CI03B871.49035 CI-06871 Monographie Bibliothèque CDI-Ouaga Fond documentaire Disponible CI03B871.49034 CI-06871 Monographie Bibliothèque CDI-Ouaga Fond documentaire Disponible CI03B871.49033 CI-06871 Monographie Bibliothèque CDI-Ouaga Fond documentaire Disponible